Orientalfiber FAC-SC/APC-03 and FAC-SC/UPC-03 are high-performance field assembly connectors designed for fast, reliable, and low-loss fiber termination. As a leading manufacturer, Orientalfiber provides these connectors to help telecom contractors, data center operators, and enterprise network teams rapidly deploy FTTH networks and data room upgrades. These connectors eliminate complex fusion splicing, reduce installation time to approximately 15 seconds per fiber, and maintain stable signal performance with low insertion loss and high return loss, making them a cost-effective and efficient solution directly sourced from a trusted China supplier.


Orientalfiber FAC-SC/APC-03 va FAC-SC/UPC-03 dala yig‘ish konnektorlari an’anaviy tolani o‘rnatishning umumiy qiyinchiliklarini, jumladan, vaqt talab qiluvchi protseduralar, murakkablik va yuqori xatoliklarni bartaraf etish uchun mo‘ljallangan. Ushbu ulagichlar yordamida texniklar termoyadroviy ulanish yoki qimmatbaho maxsus asboblarni talab qilmasdan, taxminan 15 soniya ichida bitta tolali tugatishni yakunlashlari mumkin, bu FTTH loyihalari, ma'lumotlar xonasini yangilash va korporativ tarmoq o'rnatish uchun joylashtirish samaradorligini sezilarli darajada oshiradi.


Kimga kerak

Ushbu ulagich quyidagilar uchun idealdir: - Katta hajmdagi tolani tezda joyida o'rnatishi kerak bo'lgan telekommunikatsiya pudratchilari. - Yuqori aniqlikdagi, kam yo'qotishli ulanishlarni talab qiluvchi ma'lumotlar markazi operatorlari. - Korporativ tarmoq ma'murlari ma'lumotlar xonasini yangilashni yoki LAN kengayishlarini soddalashtirishga intilishadi. - Turar-joy yoki tijorat tarmoqlari uchun tez va ishonchli tolali ulanishga muhtoj bo'lgan FTTH o'rnatish guruhlari.


Nima uchun yaxshiroq

Orientalfiber FAC konnektorlari bir necha sabablarga ko'ra ajralib turadi: -Yuqori optik ishlash:Qo'shish yo'qolishi ≤0,5dB (odatiy ≤0,3dB), qaytish yo'qolishi ≥50dB (UPC) va ≥55dB (APC), barqaror signal uzatilishini ta'minlaydi. -Mexanik va ekologik chidamlilik:500 ta juftlash aylanishiga, 20N onlayn valentlik sinoviga bardosh beradi va -40 ° C dan + 85 ° C gacha bo'lgan haroratlarda ishlaydi. -Qayta foydalanish mumkin:Ishlash darajasini saqlab, texnik xizmat ko'rsatish xarajatlarini kamaytiradigan holda 10 martadan ortiq qayta o'rnatilishi mumkin. -Tez o'rnatish:Har bir tolaga taxminan 15 soniya, termoyadroviy biriktiruvchi uskunasiz intuitiv ishlash. -To'g'ridan-to'g'ri ONU va 86-standart rozetkaga muvofiqligi:Loyihaning umumiy narxini pasaytirib, adapterlarga bo'lgan ehtiyojni kamaytiradi.


Qanday foydalaniladi 

1. Elyafni tayyorlang va oldindan o'rnatilgan uchi toza ekanligiga ishonch hosil qiling. 2. Tolani FAC ulagichiga joylashtiring, mahkamlang va muloyimlik bilan torting. 3. Darhol yuqori tezlikda, barqaror signal uzatish uchun to'g'ridan-to'g'ri ONU yoki patch panelga ulang. Oldin: Elyafni o'rnatish ko'p vaqt talab etadi, xatolarga moyil va bir necha bosqichlarni talab qiladi. Keyin: Tezkor joyida yig'ish, barqaror signal va soddalashtirilgan o'rnatish mehnat va loyiha vaqtini tejaydi.


Mijozlarning fikr-mulohazalari

Xitoydagi yirik FTTH loyihalari Orientalfiber FAC konnektorlari yordamida o'rnatish samaradorligini 40% ga oshirish va umumiy xarajatlarni 15% ga kamaytirish haqida xabar berdi. - Ma'lumotlar markazi tarmog'ining yangilanishi barqaror qo'shish va qaytarish yo'qotilishini ko'rsatdi, texnik xizmat ko'rsatish va qayta ishlashni qisqartirdi. - Ko'plab xalqaro telekommunikatsiya operatorlari energiya, temir yo'l, avtomobil yo'llari va sanoat tarmoqlarining old tomonini joylashtirish uchun ushbu ulagichlarni qabul qilishda davom etmoqdalar.


Umumiy tashvishlar

-Moslik:652 va 657 standartlariga mos keladigan, ONU va ichki kabellarga to'g'ridan-to'g'ri mos keladigan 125 mkm bir rejimli tolalarni qo'llab-quvvatlaydi. -Sifatni tekshirish:ISO9001 sifat menejmenti va ISO45001 mehnat salomatligi va xavfsizligi tizimlari bilan sertifikatlangan. -Ta'minot va logistika:Orientalfiber ommaviy buyurtmalarni o'z vaqtida yetkazib berishni ta'minlash uchun to'rtta zavod va to'liq ta'minot zanjiriga ega. -Qayta foydalanish imkoniyati:10 martadan ortiq qayta o'rnatilishi mumkin, bu doimiy ish bosimini kamaytiradi.

Nima uchun hozir harakat qiling

Orientalfiber FAC-SC/APC-03 yoki FAC-SC/UPC-03 ulagichlarini tanlash sizga quyidagilarga imkon beradi: - Tolalarni o'rnatish samaradorligini darhol oshirish - Loyiha xarajatlarini va qayta ishlash xavfini kamaytirish - Uzoq muddatli tarmoq barqarorligini ta'minlash - To'g'ridan-to'g'ri zavod ta'minoti va global yordamdan foydalaning Professional optik tolali yechim provayderi sifatida Orientalfiber telekom, FTTH, korporativ tarmoqlar va ma'lumotlar markazlari uchun ishonchli, yuqori samarali dala yig'ish konnektorlarini yetkazib beradi, bu esa murakkab tolali o'rnatishlarni sodda va samarali qiladi.



FAC-SC/APC-01

Field Assembly Connector-Fiber Pre-embeded Tech


FAC-SC/UPC-01

Field Assembly Connector-Fiber Pre-embeded Tech


FTTx ilovasi, ma'lumotlar xonasini o'zgartirish

Texnik spetsifikatsiya:

Element Parametr
Kabel doirasi 3,0 x 2,0 mm
Hajmi: 59*8.7*8.3mm va 55*8.7*8.3mm
Elyaf diametri 125 mkm (652 va 657)
Qoplama diametri 250 mkm
Rejim SM
Operatsion vaqti taxminan 15 soniya (tolani oldindan o'rnatishdan tashqari)
Qo'shishni yo'qotish ≤ 0,5dB Maks/Odatda ≤0,3dB(1310nm & 1550nm)
Yo'qotishlarni qaytarish UPC uchun ≥50dB, APC uchun ≥55dB
Muvaffaqiyat darajasi >98%
Qayta foydalanish mumkin bo'lgan vaqtlar > 10 marta
Yalang'och tolaning mustahkamligini torting >5 N
Mustahkamlik chegarasi >50 N
Harorat -40 ~ +85 S
Onlayn kuchlanish sinovi (20 N) IL diapazoni≤0,3dB RL diapazoni≤5dB
Mexanik chidamlilik (500 marta) IL diapazoni≤0,3dB RL diapazoni≤5dB
Tushish testi (4 m beton zamin, har bir yo'nalishda bir marta, jami uch marta) IL diapazoni≤0,3dB RL diapazoni≤5dB


Tegishli yechimlar:

● Oson ishlaydi, ulagich to'g'ridan-to'g'ri ONUda ishlatilishi mumkin, shuningdek, mahkamlash quvvati 5 kg dan ortiq bo'lsa, u tarmoq inqilobining FTTH loyihasida keng qo'llaniladi. Shuningdek, u rozetkalar va adapterlardan foydalanishni kamaytiradi, loyiha narxini tejaydi.

● 86 standart rozetka va adapter bilan ulagich tushirish kabeli va patch shnur o'rtasida aloqa o'rnatadi. 86 standart rozetka o'zining noyob dizayni bilan to'liq himoya qiladi.

● Dala o'rnatilishi mumkin bo'lgan ichki kabel, pigtail, patch shnur va ma'lumot xonasida patch shnurni o'zgartirish uchun qo'llaniladi va to'g'ridan-to'g'ri maxsus ONUda qo'llaniladi.



Hot Tags: FAC-SC/APC-03 FAC-SC/UPC-03 maydon yig'ish ulagichi
So'rov yuborish
Aloqa ma'lumotlari
  • Manzil

    90 Yangtanggang Road, Iqtisodiy rivojlanish zonasi, Jurong shahri, Jiangsu viloyati, Xitoy

  • Tel

Mahsulotlarimiz yoki Pritelast haqida savollar uchun iltimos, elektron pochtangizni bizga qoldiring va 24 soat ichida biz aloqada bo'lamiz.
X
Biz cookie-fayllardan sizga yaxshiroq ko'rish tajribasini taklif qilish, sayt trafigini tahlil qilish va kontentni shaxsiylashtirish uchun foydalanamiz. Ushbu saytdan foydalanish orqali siz bizning cookie-fayllardan foydalanishimizga rozilik bildirasiz. Maxfiylik siyosati
Rad etish Qabul qiling